OPTIONS
Thermocouple
Temperature (humidity) recorder
Dry [wet] bulb temperature
Ter minal board for dry-bulb/wet-bulb
sensors in the chamber.
Temperature (humidity) recorder wiring
Preparation of a power cable, temperature
sensor, relative humidity signal and a
grounding wire for additional installation
in the future.
Recorder output terminal
Temperature, humidity, and heater
output
This terminal outputs the temperature and
relative humidity in the test area.
Wet bulb wick
T he s e a r e t he s a me a s t he i n clu de d
accessories.
• Fine wicks
• Cloth wicks (PDL/PDR only)
Paperless recorder
Records the temperature and humidity of
each section such as the temperature inside
the chamber.
Data saving cycle: 5 sec.
External recording media:
CF memory card port
(Includes a 256 MB CF card)
USB memory port
No. of inputs:
< Temperature & humidity type >
Temperature 1, Humidity 1
(4 more channels can be turned ON)
< Temperature type >
Temperature 1
(5 more channels can be turned ON)
Records the temperature and humidity of
each section such as the temperature inside
the chamber.
Recording method: Dot
Recording paper: Effective width 100 mm
No. of inputs:
< Temperature & humidity type >
Temperature 5, Humidity 1
RJ11 −50 to +100°C/0 to 100% rh
RJ12 −0 to +150°C/0 to 100% rh
RJ13 −00 to +100°C/0 to 100% rh
RJ14 −00 to +150°C/0 to 100% rh
RJ15 −00 to +200°C/0 to 100% rh
< Temperature type >
Temperature 6
RJ21 −0 to +100°C
RJ23 −00 to +100°C
RJ25 −00 to +200°C
A t t a c h e d t o s p e c i m e n t o me a s u r e
specimen temperature.
Thermocouple with a brass ball tip
Thermocouple type T (Copper/Copper-Nickel)
• 2 m
• 4 m
• 6 m
35