ULTRA LOW TEMPERATURE CHAMBER
PG
70
to
100℃(+150℃180℃
Model PG−2J PG4J
System Balanced Temperature Control system (BTC system)
Performance*
1
Temperature range 70 to +10C (lowest attainable temperature in an ambient temperature of 0 to +30°C)
Temperature fluctuation ±0.3°C
Temperature gradient 3.0°C
Temperature variation in space 1.5°C
Temperature rate of change
Heat up rate: 5.0°C/min.
Pull down rate: 2.0°C/min.
Heat up rate: 5.0°C/min.
Pull down rate: 1.0°C/min.
Temperature extremes
achievement time
Heat up time: from +20 to +10C 30 min.
Pull down time: from +20 to −70°C 65 min.
Allowable heat load*
2
700 W 2200 W
Construction
Exterior material Stainless steel plate: 18 Cr stainless steel plate, hairline finish
Test area material Stainless steel plate: 188 Cr−Ni stainless steel plate, 2B polish
Heater Nichrome strip wire heater
Cooler (dehumidifier) Plate fin cooler, stainless steel tube cooler
Air circulator Cross flow fan Sirocco fan
Refrig-
eration
unit
System Mechanical cascade refrigerator system
Compressor
Rotary compressor (R404A, R508A)
Reciprocating compressor (R404A)
Scroll compressor (R404A, R508A)
Reciprocating compressor (R404A)
Refrigerator capacity 1.5 kW x 1.5 kW + 0.4 kW 3.0 kW x 3.0 kW + 0.4 kW
Expansion mechanism Electronic expansion valve, capillary tube
Capacity 306 L 800 L
Chamber total load resistance 100 kg
Dimensions*
3
Inside dimensions
(W x H x D mm)
600 x 850 x 600 1000 x 1000 x 800
Outside dimensions
(W x H x D mm)
1010 x 1690 x 1273 1410 x 1853 (1983) x 1593
Weight 460 kg 695 kg
Utility requirements
Allowable ambient conditions 0 to +40°C/up to 75% rh
Power
supply
200V AC 3ø 50/60 Hz 24.5 A 45.0 A
220V AC 3ø 60 Hz*
4
23.5 A 42.5 A
380V AC 3ø 50 Hz*
4
17.5 A 23.0 A
400V AC 3ø 50 Hz*
4
16.5 A 21.8 A
*1 The performance values are based on IEC60068-3-5:2001 under the conditions of a +23°C ambient temperature, relative humidity of 65±20%rh, rated voltage, and
no specimen inside the test area.
*2 When temperature in chamber is +20°C
*3 Excluding protrusions. Dimension indicated in ( ) includes protrusion.
*4 Compliance with CE Marking